13 October 2026 · 2 min read

Flange bolt tightening sequence: the cross pattern, step by step

Tightening a flange bolt by bolt around the circle pulls it out of parallel and crushes the gasket unevenly. How the cross (star) pattern works, with the sequences for 4, 8 and 12 bolts.

The quickest way to make a flange leak is to tighten its bolts one after another around the circle. The first bolts pull that side of the flange closed before the far side has moved. The faces end up out of parallel, the gasket is crushed on one side and barely compressed on the other, and the joint weeps as soon as it sees pressure or heat.

The cure is a cross pattern, also called a star pattern, applied in stages.

Why stages matter as much as the pattern

Each time a bolt is tightened, it slightly unloads the bolts near it, because the gasket and flange compress a little more. This is sometimes called elastic interaction. Tightening in steps lets the joint close evenly, so the last pass finds every bolt at nearly the same load.

A typical staged procedure, in line with the widely used approach in ASME PCC-1 (the guideline for pressure-boundary bolted flange joints):

  1. Snug the bolts by hand or with light torque, in the cross pattern, so the flange faces come together evenly.
  2. First pass at about 30 percent of the target torque, in the cross pattern.
  3. Second pass at about 60 to 70 percent, in the cross pattern.
  4. Third pass at 100 percent, in the cross pattern.
  5. Check passes at 100 percent, going around the circle bolt by bolt, repeated until no nut turns any further.

Always follow the procedure and torque figures specified for your joint and gasket where they exist. The gasket maker's instructions and your site's bolting procedure take priority over a general guide.

The sequences

Number the bolts clockwise around the flange, starting anywhere. Then tighten in this order on every cross-pattern pass.

4 bolts: 1, 3, 2, 4

8 bolts: 1, 5, 3, 7, 2, 6, 4, 8

12 bolts: 1, 7, 4, 10, 2, 8, 5, 11, 3, 9, 6, 12

The logic is the same for any number: each bolt is followed by the one directly opposite, then the pattern moves a quarter of the way around, so the load builds evenly across the whole face. On large flanges with many bolts, some procedures group bolts and tighten several at once with multiple tools, which is faster and even more uniform.

Getting the torque itself right

The pattern only works if each bolt actually reaches the torque called for. On anything larger than small pipework that means a controlled tool, not a slogging spanner:

Lubricate the threads and nut faces with the lubricant the torque figure assumes, use clean, undamaged studs and nuts, and fit a new gasket. Record the final torque for each flange.

On site

We supply HYTORC torque and tensioning tools in Zambia and train crews to use them on their own flanges. If a joint keeps leaking after gasket changes, talk to us about how it is being tightened. More background: why bolted joints fail.